Commercial Lighting Upgrades

Commercial LED lighting upgrades for retrofit projects.

Lumenloop manufactures and supplies UK-made luminaires for commercial LED lighting upgrades. Retrofit packages can replace inefficient fluorescent or older lighting with LED panels, downlights, battens and linear systems, supported by lighting controls, emergency lighting and renew and reuse options where appropriate.

LED retrofit luminaires Energy-efficient controls Emergency and circularity options
Existing luminaires and ceilings Replacement and retrofit packages Controls and emergency coordination TM65 / TM66 where required
Request quote

Request commercial LED upgrade pricing.

Pricing is based on the current lighting, ceiling condition, operating hours, energy objective, control method and emergency requirements.

Commercial Lighting Upgrades

Benefits and scope of commercial LED lighting upgrades.

Compared with traditional lighting, an energy-efficient LED upgrade can reduce energy consumption and maintenance demand while improving lighting quality. Actual energy performance is shaped by the existing luminaires, ceiling condition, operating hours, control method, emergency provision and any renewal requirement. Compare purchase, electricity and planned driver servicing in the whole-life lighting cost model.

Replace the complete fitting or retain a serviceable body?

A complete replacement supplies a new luminaire; refurbishment retains suitable parts of the existing fitting. Lumenloop can review both routes from fitting photographs, dimensions, quantities and the required light output. Retaining a housing depends on its condition, the space for new components and a sample assessment; it is not an assumed fit for every existing luminaire.

Existing fitting Operating hours Controls Circularity
Ceiling grid
Fluorescent modules to LED panels or recessed linear

Record the ceiling system, opening length and width, fitting depth and support detail before comparing replacement panels or linear luminaires. Check the actual body dimensions, driver position and access above the ceiling; a nominal module size alone does not establish that a replacement fits.

Downlights
Older downlights to a new LED fitting

Measure the existing cut-out, bezel diameter, ceiling thickness and available void depth. Compare the replacement's mounting and driver access alongside lumen output, glare and beam spread. A similar wattage does not confirm equivalent lighting, and an existing opening may need an agreed trim or custom configuration.

Retained body
Check renewal feasibility before assuming reuse

Photographs and a fitting reference help identify a possible refurbishment route. A sample assessment then checks the housing condition and LED conversion constraints. Confirm which parts will be retained, the proposed light output, driver and emergency arrangement before agreeing the renewal scope.

Controls
Specify the driver, wiring and emergency operation

Identify switched, mains-dimmed, DALI or Casambi operation rather than asking only for a dimmable fitting. Confirm the selected product's driver option, existing wiring and sensor requirements. Record any emergency function and testing method separately, and agree installation and commissioning responsibilities with the project team.

Upgrade Ranges

12 upgrade product options

Linear

Flow UK-made recessed LG7 linear luminaire

Flow is a UK-made recessed LG7 linear luminaire for low-glare recessed lighting for offices, schools, and retail. Available in three lengths with tunable outputs, it supports LG7 compliance, DALI dimming (/+ECO), and emergency conversion (/EMI).

Panels

Luminate direct indirect LED panel

Luminate is a direct indirect LED panel with a microprism diffuser, LG7-focused low-glare versions, Touch+DALI, Casambi and emergency options, with tunable white available as a custom configuration.

Panels

Lucid LG7-certified recessed 600x600 LED panel

Lucid is a LG7-certified recessed 600x600 LED panel with Tridonic technology, UGR<19 performance, LG7-certified glare control and output up to 3900 lm on LUCID.004 for offices, schools and healthcare environments.

Commercial Applications

LED luminaires for commercial and industrial upgrade projects.

Lumenloop matches energy-efficient LED fixtures and renewal packages to each commercial space, ceiling type, lighting design, mounting method, control strategy and maintenance constraint.

Office

LED panel lights, low-glare linear luminaires and commercial downlights can replace fluorescent office lighting where glare control, energy use, controls and emergency circuits need to stay coordinated.

Industrial

Warehouse lighting upgrades commonly use high-output battens and protected linear fittings where mounting height, ingress protection, sensor strategy and long operating hours drive energy consumption and product choice.

Hospitality

Downlights, decorative architectural fittings and dimmable control packages suit corridor, reception and amenity refurbishments where finish quality, colour consistency and emergency integration matter.

Circularity

For retained housings or renewal-led work, Lumenloop can price renew and reuse packages with TM65 or TM66 support where the project team needs circularity information.

Specification Support

Technical evidence for commercial LED retrofit quotations.

Commercial LED lighting upgrades need more than a list of replacement lamps. Product data, lighting technology, controls, emergency and manufacturing information help compare the new LED lighting system with the current installation and understand its expected lifespan.

Circularity information

Where the project asks for embodied carbon or circularity information, Lumenloop can supply TM65 figures and TM66-aligned notes where available.

Controls

DALI, Casambi, sensor and switched packages are priced by control method, driver requirement and commissioning scope.

Product schedule

The schedule can separate new luminaires, renewal components, emergency variants and custom configuration items so contractors can price the package cleanly.

UK manufacture

UK build and project configuration keep output, finish, emergency packs and control gear decisions close to the quotation stage.

Commercial Upgrade FAQ

Commercial LED lighting upgrade questions.

These are the commercial questions that usually shape whether a project needs full replacement luminaires, renewal work, controls changes or emergency updates.

Can Lumenloop price a commercial lighting upgrade around existing fittings?

Lumenloop can price the upgrade around the existing fitting type, ceiling condition, mounting detail, controls and emergency requirements, whether the project needs full replacement luminaires or renewal-led work.

What luminaires are commonly used on LED retrofit projects?

Commercial LED retrofit projects commonly use replacement panels, commercial downlights, battens, linear luminaires and emergency products, matched to ceiling type, glare target, output and access constraints.

Can lighting controls be included as part of the upgrade package?

Lumenloop can supply separate DALI, Casambi, sensor and switched packages, with driver requirements, wiring implications and commissioning scope kept clear at quotation stage.

How is emergency lighting handled on replacement projects?

Emergency lighting can be priced as part of the upgrade package, including integrated emergency variants, dedicated emergency luminaires and exit signs where the replacement scope needs them.

Can Lumenloop support renewal work instead of full luminaire replacement?

Where the project is better suited to retained housings or renewal-led work, Lumenloop can support renew and reuse packages and provide circularity information where available.

What information helps Lumenloop price the upgrade?

Existing fitting photos, mounting detail, ceiling type, operating hours, control method, emergency requirement and target outcome make it easier to build the replacement quotation around the real installation.

Upgrade Pricing

Request pricing for a commercial LED lighting upgrade.

Send the fitting reference, photographs and quantity for each type, with ceiling openings, available depth and mounting details. Include the required output, driver or control method and emergency testing arrangement. If reuse is being considered, identify the fittings available for a sample assessment.

For the savings comparison, include existing and proposed system wattage and annual operating hours. Keep the luminaire supply quotation separate from installation costs when using the calculators below; estimated energy savings do not confirm physical fit or lighting performance.

Check the upgrade saving against its installed cost

Use the commercial lighting energy savings calculator with the existing load, replacement load and operating hours. Compare the complete installed cost using the LED payback calculator.