Sensors and switches
Occupancy sensors, daylight sensors and switches provide input to the lighting controls.
Lumenloop commercial LED luminaires are available with DALI control across selected downlights, linear lighting, LED panels, spotlights and wall-mounted fittings. Compare mounting, lumen output, colour temperature and emergency options across the range.

The range includes recessed downlights, linear luminaires, LED panels, spotlights and wall-mounted fittings. Available control options vary by family and may include DALI dimming, tunable white and DALI emergency gear.
No products are available with this combination of filters. Other control configurations may be available on request.
A DALI lighting system connects sensors, switches, application controllers and LED drivers on a two-wire digital control bus. Compatible luminaires can then be addressed, grouped, dimmed and monitored through the controls system.
Occupancy sensors, daylight sensors and switches provide input to the lighting controls.
Manages luminaire groups, lighting scenes and responses to sensor inputs.
Receives digital commands and controls the connected LED module.
Panels, downlights and linear luminaires connect to compatible DALI LED drivers.
Provides the power required for communication on the DALI bus.
The bus carries digital commands between control devices and control gear on the subnet.
A DALI-2 subnet supports up to 64 control gear and 64 control devices. Larger systems use multiple subnets.
A compatible gateway can exchange defined lighting data and commands with a building management system.
System structure and subnet limits follow DALI Alliance guidance. Read the official DALI systems overview.


DALI-2 is the current certification programme based on IEC 62386. It adds control devices to the certification scope and uses independently verified test specifications to improve multi-vendor interoperability.
Product cards identify luminaires available with a DALI control option. DALI-2 certification applies to the specific driver or control device, and certified product details are recorded in the DALI Alliance database.
Commercial DALI installations combine luminaire selection with control zones, sensors, lighting scenes, emergency monitoring, BMS integration and commissioning.
Individually addressed luminaires can be assigned to groups for local control, scheduled operation and scene changes.
Occupancy time-outs, daylight response and manual overrides are configured for the way each space is used.
Programmed scenes can support presentation, cleaning and after-hours lighting where different operating states are required.
Compatible emergency control gear can support automated testing, status reporting and connection to a monitoring system.
A compatible gateway connects defined DALI lighting data and commands to the building management system.
Device addressing, group assignment, scene programming and functional testing form part of the commissioning record.
DALI emergency control gear is covered by IEC 62386 Part 202 and identified as device type 1, or DT1. It can support automated function and duration testing, status reporting and integration with a wider monitoring system.
A complete DALI emergency lighting specification covers emergency duration, test schedules, status reporting, monitoring interfaces and record management. Emergency gear and controls are selected for the required system architecture.
Read the DALI Alliance emergency guideA complete schedule identifies the luminaire, optical performance, DALI control gear, control devices, emergency equipment and commissioning requirements for each area.
Operating hours, occupancy, daylight, local controls and lighting scenes establish the controls requirement for each area.
Lumen output, light distribution, colour temperature and glare control determine the required luminaire configuration.
The product code identifies the driver, dimming range, DALI version and any self-test or DALI emergency control gear.
Subnets, application controllers, sensors, switches, bus power supplies and BMS gateways form the controls architecture.
Device addressing, operating-state tests and emergency test records provide the final commissioning information.
DALI is a digital protocol for lighting control. It allows compatible control devices and control gear to exchange commands and status information over a two-wire bus.
DALI-2 is the current certification programme. It covers control devices as well as control gear, and certified products are independently verified against DALI Alliance test specifications.
Yes. Self-contained emergency control gear is covered by IEC 62386 Part 202, known as device type 1. The completed system specification covers testing, monitoring and reporting.
DALI-2 compatibility is determined by the specific driver, its certification and any required device-type support. Certified product details are available in the DALI Alliance product database.
Yes, through a suitable interface or gateway. The required data points, control permissions and integration responsibility should be agreed before commissioning.