Eco low-glare LED downlight

The Eco LED Downlight uses Philips LED technology with high efficacy and sustainability-focused product options.

Talk through an Eco specification Call 02045 721 554 Email Specification Team
Professional low glare downlight

With a wide choice of options

Multi-faceted 40 deg reflector as standard

Supports controlled distribution and visual comfort in the finished ceiling.

Other reflector styles and

Beam angles available

Luminaire efficacies up to 144 llm/tcW

Output reference for specification and comparison.

Luminaire type Low-glare LED downlight
Life >66,000 hours (L90) Use as a reference for planned maintenance intervals.
Professional low glare downlight With a wide choice of options
Download Datasheet Technical datasheet for specification review. Installation Guide Installation guide for site coordination.
Project selection Configure the required luminaire option and available accessories below.
Configure For Enquiry

Configure Eco for enquiry.

Configuration options cover output, optic, finish, control gear and accessories for specification support.

Configured Specification

Selected Eco specification.

Model code
ECO.001
Product codeECO.001
Specification check1,000 lm | 8.0 W | 3000K | 3000K
Option suffixesNo option suffixes selected.
AccessoriesNo separate accessory codes selected.
Request Specification Support
Model code
ECO.001
Technical Description

Low-glare LED downlight specification for Eco.

The Eco LED Downlight uses Philips LED technology with high efficacy and sustainability-focused product options. With module efficacies reaching up to 192 lumens per watt, this downlight offers a range of options for both performance and control, making it suitable for a variety of applications

Performance and installation details include life >66,000 hours (L90): use as a reference for planned maintenance intervals. Review output, optics, mounting and control requirements against the project schedule.

Available technical files are shown with this product.

Specification-led low-glare LED downlight features.

  • Professional low glare downlight: With a wide choice of options
  • Multi-faceted 40 deg reflector as standard: Supports controlled distribution and visual comfort in the finished ceiling.
  • Other reflector styles and: Beam angles available
  • Luminaire efficacies up to 144 llm/tcW: Output reference for specification and comparison.
  • Philips LED and driver system: Gives the product range a recognised LED and driver platform.
  • IP54 & IP65 options: Helps confirm the environmental or compliance requirement before ordering.
  • Increased energy efficiency upgrades: Supports the selected specification.
  • Dimming, emergency, DALI and: Wireless network control options
Model codesECO.001
Life >66,000 hours (L90)Use as a reference for planned maintenance intervals.
Luminaire efficacies up to 144 llm/tcWOutput reference for specification and comparison.
Specification resourcesDownload Datasheet, Installation Guide
Body And Trim Detail

Eco technical reference.

The Eco LED Downlight uses Philips LED technology with high efficacy and sustainability-focused product options.

Key specification points include life >66,000 hours (L90): use as a reference for planned maintenance intervals.

Option notes include Controls: Tunable white + DALI /T+DALI, Casambi wireless /BTC and Wireless mesh with integral indicator /EMMI. Emergency: 3-hour emergency /EM, Self-test / DALI emergency /EMD, Wireless mesh emergency /EMM, Maintained emergency /EMI and DALI emergency /EMDI. Available technical files are shown with this product.

Eco LED downlight white trim view
Specification Choices

Build the Eco specification.

Output and CCT
ECO.001

1,000 lm | 8.0 W | 3000K | 3000K

Output and CCT
ECO.002

1,050 lm | 8.0 W | 4000K | 4000K

Output and CCT
ECO.003

1,750 lm | 13.5 W | 3000K | 3000K

Output and CCT
ECO.004

1,825 lm | 13.5 W | 4000K | 4000K

Output and CCT
ECO.005

2,425 lm | 19.0 W | 3000K | 3000K

Output and CCT
ECO.006

2,525 lm | 19.0 W | 4000K | 4000K

Output and CCT
ECO.007

3,250 lm | 27.0 W | 3000K | 3000K

Output and CCT
ECO.008

3,375 lm | 27.0 W | 4000K | 4000K

Output and CCT
ECO.009

4,375 lm | 40.0 W | 3000K | 3000K

Output and CCT
ECO.010

4,550 lm | 40.0 W | 4000K | 4000K

Options And Accessories

Eco options, finishes and controls.

Controls
/T+DALI/BTC/EMMI

Tunable white + DALI /T+DALI; Casambi wireless /BTC; Wireless mesh with integral indicator /EMMI

Emergency
/EM/EMD/EMM/EMI/EMDI

3-hour emergency /EM; Self-test / DALI emergency /EMD; Wireless mesh emergency /EMM; Maintained emergency /EMI; DALI emergency /EMDI

Specification reasons

Why specify Eco?

Optics
Professional low glare downlight

With a wide choice of options

Optics
Multi-faceted 40 deg reflector as standard

Supports controlled distribution and visual comfort in the finished ceiling.

Optics
Other reflector styles and

Beam angles available

Performance
Luminaire efficacies up to 144 llm/tcW

Output reference for specification and comparison.

Selection point
Philips LED and driver system

Gives the product range a recognised LED and driver platform.

Selection point
IP54 & IP65 options

Helps confirm the environmental or compliance requirement before ordering.

Eco LED downlight heatsink detail
Product FAQs

Eco specification questions.

Specification notes for contractors, consultants and buyers checking low-glare LED downlight options before ordering.

What makes Eco different from a standard low-glare LED downlight?

The Eco LED Downlight uses Philips LED technology with high efficacy and sustainability-focused product options. With module efficacies reaching up to 192 lumens per watt, this downlight offers a range of options for both performance and control, making it suitable for a variety of applications

Which ceilings or mounting conditions should be checked for Eco?

Check the mounting method, ceiling construction, access space and installation guide before the luminaire is added to the final schedule.

Which outputs, wattages and colour temperatures are available?

Life >66,000 hours (L90): use as a reference for planned maintenance intervals. Output, colour temperature, control gear and emergency options vary by configuration.

What controls and emergency options can be specified?

Controls: Tunable white + DALI /T+DALI, Casambi wireless /BTC and Wireless mesh with integral indicator /EMMI. Emergency: 3-hour emergency /EM, Self-test / DALI emergency /EMD, Wireless mesh emergency /EMM, Maintained emergency /EMI and DALI emergency /EMDI. Check the control strategy, emergency requirement and selected base model before quotation.

Can finishes, accessories or product variations be specified?

Multi-faceted 40 deg reflector as standard: Supports controlled distribution and visual comfort in the finished ceiling.

Are photometric, BIM or installation files available?

Available files include the datasheet and installation guide for specification work and installation planning.

What lead time should be allowed for Eco?

Lead time depends on quantity, finish, control gear, emergency conversion and current production capacity. Confirm the current project lead time with Lumenloop before placing an order.

Project Enquiry

Check product options and datasheets.

Model code, room type, control preference and accessory requirements help identify the correct datasheets, option notes and technical files.

Project Details

Check the datasheet, output options and control requirements before adding the fitting to a schedule.