Specify the Aegis vapour-proof LED batten across eight 4 ft and 5 ft models, with outputs from 3,675 to 9,250 lumens and dedicated three-hour emergency options.

Lengths
4 ft and 5 ft
Output range
3,675–9,250 lm
Emergency options
/EMI and /EMDI
Aegis vapour-proof LED batten mounting detail
Aegis · surface-mounting detail

A complete specification

Start with the luminaire, then add the emergency function

Each Aegis code identifies the batten length, normal-lighting output and power. The emergency suffix is selected afterwards, so the base model and emergency gear remain clear in the project schedule.

The range uses an IP65, IK08 vapour-proof enclosure and provides eight 4000K base models. Controls, sensors, plug-and-play wiring and mounting accessories can then be considered alongside the emergency conversion.

Normal-lighting lumens in the tables below describe the base luminaire. Emergency output, battery arrangement and project spacing should be confirmed from the emergency specification and layout for the selected conversion.

Selection sequence

Four decisions build the schedule

Keep the model choice, emergency conversion and control requirements visible as separate decisions.

Choose the length

Select a 4 ft or 5 ft body to suit the installation geometry, fixing centres and available space.

Set normal output

Choose from four lumen packages at each length, covering 3,675 to 9,250 lumens across the range.

Select emergency gear

Use /EMI for a three-hour emergency conversion or /EMDI for the three-hour DALI emergency option.

Add project options

Coordinate dimming, occupancy sensing, QuickWire connection and mounting accessories with the base code.

Aegis range

All eight base models

Four output levels are available in each body length, giving a continuous specification route from compact installations to higher-output areas.

IP65 · IK08 · 4000K

Aegis

A vapour-proof LED batten with control, emergency and installation options organised around one consistent model family.

Models
8 base codes
Power
23–59 W
Output
3,675–9,250 lm
4 ft models
CodePowerOutputCCT
AEGIS.00123 W3,675 lm4000K
AEGIS.00228.5 W4,475 lm4000K
AEGIS.00334.5 W5,325 lm4000K
AEGIS.00440.5 W6,100 lm4000K
5 ft models
CodePowerOutputCCT
AEGIS.00533 W5,300 lm4000K
AEGIS.00641.5 W6,625 lm4000K
AEGIS.00750 W7,950 lm4000K
AEGIS.00859 W9,250 lm4000K

Options and accessories

Every listed addition

Use the relevant suffix or accessory code alongside the chosen Aegis base model.

Controls

/ECO
DALI, SwitchDIM or DSI control gear.
/BTC
Casambi-compatible wireless dimming.
/SO
PIR sensor with on/off control.
/SD
PIR sensor with dimming control.

Emergency

/EMI
Three-hour emergency conversion.
/EMDI
Three-hour DALI emergency conversion.

Connection and mounting

/PAP
Three-pole QuickWire plug-and-play connector for three-core wiring.
AEGIS.ACC.01
Two-metre suspension kit.
AEGIS.ACC.02
Corner mounting kit.

Accessories

AEGIS.ACC.03
16-piece anti-tamper fixing kit.
AEGIS.ACC.04
Sensor programming remote.

Code-building example

Keep the schedule legible

Record the base luminaire and required additions explicitly rather than treating “emergency batten” as a complete specification.

STEP 01

Select the base model

Choose length, normal output and power first.

AEGIS.006
5 ft · 41.5 W · 6,625 lm · 4000K
STEP 02

Add emergency

State the required three-hour emergency conversion.

/EMI standard emergency
/EMDI DALI emergency
STEP 03

Record other additions

List controls, sensor, connector and accessory requirements separately.

/ECO DALI control gear
AEGIS.ACC.02 corner kit

Project checks

Information to settle before ordering

A robust schedule combines product selection with the emergency layout, control strategy and installation method.

Emergency layout

Confirm luminaire positions and the required emergency performance from the project design.

Normal output

Choose the base model against the normal-lighting calculation, mounting height and spacing.

Control strategy

Decide whether the project needs fixed output, wired dimming, Casambi or integrated PIR sensing.

Mounting route

Record surface, suspended or corner mounting requirements and any accessory codes.

Testing information

Coordinate the selected emergency gear with the project commissioning and testing approach.

Complete schedule

Keep model, emergency, controls, connection and accessories visible in the final luminaire schedule.

Frequently asked questions

Emergency LED batten FAQs

Answers based on the current Aegis model and option list.

How many Aegis base models are available?

There are eight: AEGIS.001 to AEGIS.004 in 4 ft, and AEGIS.005 to AEGIS.008 in 5 ft.

Which emergency options are listed?

/EMI provides a three-hour emergency conversion, while /EMDI provides a three-hour DALI emergency conversion.

Does the stated lumen output describe emergency mode?

No. The table shows the normal-lighting output of each base luminaire. Confirm emergency performance separately for the selected conversion and layout.

Can controls be added?

Yes. Listed choices include DALI, SwitchDIM or DSI gear, Casambi-compatible wireless dimming, and PIR sensor options.

What mounting accessories are available?

The range lists a two-metre suspension kit and a corner mounting kit, plus an anti-tamper fixing kit.

What environmental ratings does Aegis have?

The current range information lists IP65 ingress protection and IK08 impact resistance.

Project support

Send the batten and emergency brief

Share the layout, mounting height, target normal-lighting levels and required emergency strategy. Lumenloop can help turn those requirements into a clear Aegis schedule.

  • Site type and environmental conditions
  • 4 ft or 5 ft preference
  • Normal-lighting output requirement
  • Emergency and control approach
  • Mounting and wiring method