Glide 177

high efficacy light uk casambi wireless lighting control dali options available emergency light

Upgrade your workspace with the Glide 177, a 4ft LED batten featuring Tridonic technology and ultra-high efficacy up to 131 lm/tcW.

Designed for warehouses, offices, and industrial spaces, this aluminium-bodied luminaire delivers outputs from 2925 lm (177.001) to 5200 lm (177.004) with 840 CCT for crisp, uniform light.

Integrate DALI dimming (/ECO)self-test emergency modules (/EMDI), or smart motion sensors for energy savings.

Compliant with UK standards and backed by a 5-year warranty, the Glide 177 is built for durability and ease of installation with BESA fix mounting.

 

📄 Download Datasheet

📄 Photometric Data

📄 Bim File

uk-made lighting 5 year warranty lighting low glare lights

Glide 177 LED Batten: The Ultimate T4 LED Tube Replacement for 4ft Fluorescents

Are you searching for flicker-free LED tube lighting to replace your outdated 4ft fluorescent tubes? The Glide 177 Series delivers superior retrofit LED tube solutions engineered specifically for British commercial and industrial environments.

These premium fluorescent to LED tube replacements combine Tridonic’s advanced lighting technology with robust aluminium construction—perfect for facilities managers and electricians seeking hassle-free 4ft LED tube upgrades with immediate energy savings.

 

Technical Specifications for 4ft LED Tube Replacements

Model Light Output (lm) Power Consumption (tcW) Efficacy (lm/tcW) Colour Temperature
177.001 2,925 22.5 130 4000K (Cool White)
177.002 3,675 28.5 129 4000K (Cool White)
177.003 4,450 34.0 131 4000K (Cool White)
177.004 5,200 40.0 130 4000K (Cool White)

Product Lifespan: 50,000+ hours (L70/B50)
Colour Rendering: Ra>80 for accurate colour representation
Beam Angle: 120° for uniform illumination compared to 360° of traditional 4ft fluorescents
Power Factor: >0.95 for electrical efficiency
Input Voltage: 220-240V (50/60Hz)
Installation Rating: IP20 as standard, optional IP54 diffuser available
Operating Temperature: -20°C to +40°C
Warranty: 5-year comprehensive coverage
Compliance: UKCA-certified, meets Part L building regulations, LIA certified

 

Emergency Lighting Solutions for 4ft Fluorescent Replacements

When replacing 4ft fluorescent emergency fittings, compliance with British safety standards is essential. Our emergency options ensure your facility meets all current regulations:

Option Description Compliance Testing Method
/EMI Basic 3-hour emergency module Meets BS 5266 emergency lighting requirements Manual testing required
/EMDI DALI self-test emergency with automatic compliance checks BS 5266 compliant with automated testing Self-tests with automatic reporting
Combination Systems Networked emergency monitoring Exceeds BS 5266 with centralised monitoring Centralised automated testing

 

Understanding Your Upgrade: 4ft Fluorescent Tubes vs T4 LED Tube Replacements

What are traditional 4ft fluorescent tubes? For decades, 4ft fluorescent tubes have been the standard in British commercial lighting, commonly found in offices, schools, hospitals, and industrial settings.

Traditional T4 fluorescent tubes specifically have a 12mm diameter (compared to the 26mm T8 or 16mm T5 varieties) and are frequently used in under-cabinet lighting, emergency exit signs, and display cases. These conventional 4ft fluorescent fittings typically operate at 30-58W, require electromagnetic or electronic ballasts that cause flickering, and contain mercury that demands specialist disposal.

 

Comparison: 4ft Fluorescent vs. Glide 177 LED Tube Replacement Traditional 4ft Fluorescent Tube Glide 177 LED Tube Replacement
Energy Efficiency 40-65 lumens per watt Up to 131 lumens per watt (50% more efficient)
Power Consumption 30-58W typical for 4ft tubes As low as 22.5W for equivalent output
Annual Energy Cost (per fixture)* £29-£56 £12-£22 (£17-£34 annual savings per fixture)
Lifespan 10,000-20,000 hours 50,000+ hours (L70/B50)
Replacement Frequency Every 2-3 years in commercial use 5+ years with minimal light degradation
Flicker Common as ballasts age 100% flicker-free operation for better workplace wellbeing
Warm-up Time 1-3 minutes to full brightness Instant-on at full brightness, even in cold environments
Control Options Limited dimming capabilities DALI, SwitchDIM, Bluetooth, motion sensors
Maintenance Costs Regular tube and ballast replacements Minimal 5+ year maintenance-free operation
Contains Mercury Yes – special disposal required No – environmentally friendly, WEEE compliant
Operating Temperature Performance drops in cold environments Consistent performance in all temperatures
Light Degradation Up to 30% light loss before failure Less than 30% light loss after 50,000 hours
UV Emission Yes – can fade textiles and artwork No – safer for sensitive environments

*Based on 10 hours daily operation at £0.27/kWh

 

The 4ft Fluorescent Ban: Why Now Is the Time to Upgrade to LED Tube Replacements

In accordance with recent UK and EU regulations, T4 and other fluorescent lighting containing mercury can no longer be manufactured or imported into the UK.

This legislative change means businesses and facility managers must find compliant alternatives for their 4ft fluorescent tube installations. The Glide 177 LED batten series offers a fully compliant replacement solution that exceeds all UK building regulations whilst delivering substantial cost savings.

 

Key Features of Our 4ft LED Tube Replacement Solution

Engineered for Seamless Fluorescent to LED Tube Replacements in British Commercial Buildings

Direct Retrofit Installation: Replaces standard 4ft fluorescent battens with no rewiring required

Ultra-High Efficiency: Achieves up to 131 lm/tcW (Model 177.003) for maximum energy savings

Building Regulation Compliant: Exceeds Part L requirements for commercial lighting efficiency

Flicker-Free Performance: Consistent, stable light output eliminates eye strain and headaches

Premium British-Approved Construction: Aluminium body with integrated gear tray and opal diffuser

Smart-Ready Design: Compatible with DALI, Casambi Bluetooth, and HubSense systems

Emergency Lighting Options: Self-test DALI or basic emergency modules available to BS 5266 standards

Quick Installation: BESA fix mounting points and 20mm conduit entries for fast retrofits in UK buildings

Health & Wellbeing Benefits: Better colour rendering and uniformity compared to 4ft fluorescents

Extended Warranty: 5-year comprehensive coverage for peace of mind

 

Choosing the Right 4ft LED Tube Replacement for Your Specific Environment

When selecting a replacement for your 4ft fluorescent tubes, consider these equivalency guidelines for the Glide 177 series:

Existing 4ft Fluorescent Tube Recommended Glide 177 Model Light Output Comparison Energy Saving
1x36W T8 Fluorescent (3350lm) 177.001 (2925lm) Similar perceived brightness due to directional efficiency Up to 38%
1x58W T8 Fluorescent (5200lm) 177.002 (3675lm) Similar perceived brightness due to directional efficiency Up to 51%
2x36W T8 Fluorescent (6700lm) 177.003 (4450lm) Similar perceived brightness due to directional efficiency Up to 53%
2x58W T8 Fluorescent (10400lm) 177.004 (5200lm) Effective replacement for most applications Up to 66%
1x28W T5 High Efficiency 177.001 (2925lm) Direct upgrade with improved performance Up to 20%
1x49W T5 High Efficiency 177.002 (3675lm) Direct upgrade with improved performance Up to 42%
2x28W T5 High Efficiency 177.003 (4450lm) Direct upgrade with improved performance Up to 39%
2x49W T5 High Efficiency 177.004 (5200lm) Direct upgrade with improved performance Up to 59%

 

Smart Control Options for Your LED Tube Lighting

Maximise Your Cost-Saving Lighting Upgrades with Intelligent Controls

Traditional 4ft fluorescent tubes offer limited control options, typically just on/off. Our Glide 177 LED tube replacements provide sophisticated control capabilities that can generate additional energy savings of 30-45% beyond the basic replacement benefits.

Control Type Features Best For Additional Energy Savings
/ECO SwitchDIM, DALI, or DSI dimming capability Integration with building management systems 20-30%
Motion Sensors Available with on/off or 10% dimming modes Corridors, storerooms, and low-traffic areas 30-45%
Daylight Harvesting Automatic adjustment based on available natural light Perimeter offices and atriums 15-25%
Casambi Bluetooth Wireless app-based control without additional wiring Retrofit projects where rewiring is difficult 25-35%
HubSense Wireless Scalable wireless mesh network for large installations Campus-wide lighting management 25-40%
Time Scheduling Programmed operation based on building usage patterns Regular-hours facilities like schools 10-20%

 

Why British Facilities Managers Choose Our Retrofit LED Tube Solutions

The Economical Choice for Fluorescent to LED Tube Replacements

  1. Immediate Energy Savings: Cut power consumption by up to 60% compared to traditional 4ft fluorescent tubes
  2. Reduced Maintenance: 5x longer lifespan than fluorescent tubes means fewer replacements and lower labour costs
  3. Improved Workplace Wellbeing: Flicker-free LED tube lighting reduces eye strain, headaches, and absenteeism
  4. Fast ROI: Average payback period of 12-18 months on energy savings alone in UK facilities
  5. Future-Proof Investment: Smart-ready for IoT integration and building automation
  6. Compliance Assurance: Meets all current UK regulations following the fluorescent tube ban
  7. Enhanced Safety: No mercury or hazardous materials requiring specialist disposal
  8. Improved Light Quality: Better colour rendering and uniformity compared to 4ft fluorescents
  9. Reduced Carbon Footprint: Lower energy consumption means reduced carbon emissions to support sustainability goals
  10. Lower Heat Output: Cooler operation reduces HVAC load, generating additional energy savings

 

Installation Simplicity for British Electricians

Our 4ft LED tube replacements are designed for easy installation in UK commercial buildings:

  • 15-Minute Retrofit: Direct replacement for existing 4ft fluorescent fixtures with standard UK mountings
  • Flexible Mounting: Standard BESA mounting points and 20mm conduit entries compatible with British electrical systems
  • No Special Tools: Standard installation process familiar to all UK-qualified electricians
  • Comprehensive Documentation: Full installation guides and wiring diagrams provided
  • Technical Support: UK-based technical helpline available for installation assistance
  • Complete Kit: All necessary components included in one package
  • Minimal Disruption: Quick installation means less downtime for occupied buildings

 

Technical Appendix: Detailed Comparison Between T4 Fluorescent Tubes and LED Replacements

Parameter Traditional T4 Fluorescent T4 LED Tube Replacement (Glide 177)
Tube Diameter 12mm Integrated LED (no tube)
Standard Lengths 150mm – 1200mm 600mm, 1200mm, 1500mm
Power Consumption Range 4W – 54W 22.5W – 40W
Luminous Efficacy 40-65 lm/W Up to 131 lm/W
Colour Temperature Options 3000K, 4000K, 6500K 3000K, 4000K, 6500K (4000K standard)
Colour Rendering Index Ra 60-85 Ra >80
Starting Method Requires starter and ballast Instant electronic
Cold Temperature Performance Poor starting below 5°C Excellent (-20°C to +40°C)
Ballast Compatibility Requires compatible ballast Direct mains connection (no ballast)
Dimming Capability Limited, requires special ballast Fully dimmable with multiple protocols
Mercury Content 3-5mg per tube None
UV Radiation Yes – can fade materials None
Disposal Requirements WEEE regulated waste Standard WEEE recycling
Average Lifespan 10,000-20,000 hours 50,000+ hours
Impact Resistance Fragile glass tube Durable polycarbonate diffuser
Operating Cost (£/1000hrs) £2.70 – £5.40 £1.08 – £1.94
Typical Applications Under-cabinet, display, emergency All general and task lighting applications

 

📄 Download Datasheet

📄 Photometric Data

📄 Bim File

FAQ

Yes, all of our luminaires are available with dimmable LED drivers.

  • Mains Dimming (/MDIM): This allows dimming through standard phase-cut dimmers.

  • SwitchDIM, DALI, or DSI (/ECO): These options provide compatibility with SwitchDIM, Digital Addressable Lighting Interface (DALI), or Digital Serial Interface (DSI) systems for more advanced lighting control.

  • Casambi Wireless Network (/BTC): This enables wireless dimming and control via the Casambi platform, offering flexibility and ease of use.

Yes, we offer a comprehensive range of emergency lighting solutions to ensure safety and compliance with UK regulations. Our offerings include:

  • Maintained Emergency Lighting: These luminaires operate continuously under normal conditions and remain illuminated during a power failure, providing consistent illumination in critical areas.

  • Non-Maintained Emergency Lighting: These units remain off during normal operation and activate only when the mains power fails, ensuring energy efficiency while still providing essential illumination during emergencies.

  • Emergency Exit Signage: Designed to guide occupants safely during evacuations, our exit signs are available in various formats, including surface-mounted and recessed options, to suit different building designs and requirements.

These solutions are designed to provide dependable performance during critical moments, ensuring safety and visibility across various environments.

Our lighting solutions utilise the latest LED technology to maximise energy efficiency, helping to reduce energy consumption and lower operational costs.

Yes, all Lumenloop luminaires are supplied with compatible drivers to ensure optimal functionality and straightforward installation. We use premium driver brands like Tridonic and Philips to ensure they have long life expectancies.

All our products are proudly designed and manufactured in the UK, ensuring the highest quality standards.

Yes, we work closely with clients to develop bespoke lighting solutions tailored to their specific needs and design requirements.

Just reach out to us at info@lumenloop.co.uk

Our products are designed for various environments, with IP ratings from IP20 for indoor applications to IP65 for harsher conditions such as outdoor or industrial spaces.

Yes, as a WEEE-certified member of Recolight, we offer free recycling services for old lighting fixtures to support sustainable waste management.

Yes, many of our luminaires incorporate recycled components, supporting our commitment to sustainable manufacturing. Look out for the ‘98% recycled‘ product icon for those luminaires that are mostly made from recycled materials.

Yes, our luminaires are designed to integrate seamlessly into retrofit projects, making it easy to upgrade existing lighting systems with minimal disruption.

Lumenloop’s emergency lighting solutions are designed to fit a wide variety of installations, making them ideal for retrofit projects of all types.

Yes, Lumenloop luminaires are available in a wide range of colours and finishes to suit diverse design needs.

Most of our luminaires are customizable with a variety of RAL colour options, allowing you to match your lighting seamlessly with your interior decor or branding requirements.

This includes (but is not limited to) popular finishes such as RAL9010 (Pure White), RAL9003 (Signal White), RAL9005 (Jet Black), and RAL9016 (Traffic White), among many others.

We offer options that cater to both standard and bespoke requirements, ensuring that no matter the space, you can achieve the perfect lighting aesthetic while maintaining functionality. This flexibility in colour and finish makes our luminaires ideal for a variety of applications, from commercial spaces to more design-sensitive environments.

Yes, Lumenloop luminaires can be easily integrated with smart systems for enhanced control and flexibility.

Our products support a variety of popular smart lighting technologies, including Casambi, which allows for wireless control via Bluetooth. This means you can adjust light levels, set scenes, and even schedule lighting events directly from your mobile device or through a central system.

Additionally, our luminaires are compatible with other smart control systems such as DALI (Digital Addressable Lighting Interface), DSI (Digital Serial Interface), and SwitchDIM. These options provide versatile, scalable control for a range of environments, ensuring that Lumenloop luminaires can fit into your existing smart building infrastructure seamlessly.

Yes, Lumenloop products are fully compliant with both UK and EU safety standards, ensuring reliable and safe lighting solutions for a wide range of applications.

Lumenloop luminaires comply to regulations, including the BS EN 60598-1 standard for general requirements for luminaires, as well as specific standards for emergency lighting.

We ensure that our emergency lighting systems undergo rigorous testing to meet the requirements of the latest emergency lighting regulations, including the necessary duration for emergency operation and testing protocols, providing peace of mind for both users and regulatory bodies.

Yes, Lumenloop offers refurbishment services for older light fittings, helping to extend their lifespan and improve energy efficiency.

Our ‘UK Renew & Reuse’ workshop can upgrade your existing luminaires with the latest technology, such as LED retrofitting, modern dimming controls, and energy-efficient drivers, to ensure compliance with current standards and enhance performance.

We understand the value of your existing installations and offer bespoke solutions to suit your specific requirements.

Yes, Lumenloop’s industrial range of luminaires are built to withstand demanding environments, including high-moisture and high-heat settings.

Many of our products are designed with robust construction and high-quality materials that ensure reliability and durability in challenging conditions.

Blog